Control mode: |
Sensorless vector control(SVC); V/F control |
Startup torque: |
0.5Hz/150%; 0.5Hz/100% |
Speed range: |
-1.1; 1:50 |
Speed stability accuracy: |
±0.5%; ±1% |
Carrier frequency: |
0.5kHz ~ 16kHz; the carrier frequency is automatically adjusted based on the load features. |
Overload capacity: |
G type: 60s for 150% of the rated current, 1s for 180% of the rated current; P type: 60s for 120% of the rated current, 1s for 150% of the rated current. |
Torque boost: |
Fixed boost; Customized boost 0.1% ~ 30.0%. |
Running command source: |
Three command source:operation panel; control terminals; serial communication port; You can perform switchover between these sources in various ways. |
Frequency source: |
There are 10 frequency sources in total, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting; You can perform switchover between these sources in various ways. |
Auxiliary frequency source: |
There are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis. |
Input terminal: |
◆ 6 digital input terminals (DI); ◆ 2 analog input terminals (AI) |
Output terminal: |
◆ 1 open-collector output terminal ; ◆ 2 relay output terminal; ◆ 2 analog output terminal |
DC braking: |
Braking time: 0.0s ~ 100.0s; Braking action current value: 0.0% ~ 100.0% |
V/F curve: |
Three modes: straight-line V/F curve, multi-point V/F curve, square V/F curve. |
Ramp mode: |
Straight-line ramp, S-curve ramp; Four kinds of acceleration/deceleration time with the range of 0.0-6500.0s. |
Simple PLC/Multiple speeds: |
It implements up to 16 speeds via the simple PLC function or combination of DI terminal states. |
Built-in PID: |
It realizes process-controlled closed loop control system easily. |
AVR function: |
It can keep constant output voltage automatically when the mains voltage changes. |
Overvoltage/Overcurrent stall control: |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage and overcurrent. |
Rapid current limit: |
It helps to avoid frequent overcurrent faults of the AC Drive. |
Torque limit and control: |
It can limit the torque automatically and prevent frequent over current tripping during the running process. |
Timing control: |
Timing control function: time range: 0h ~ 65535h |
Protection mode: |
Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection and so on. |